Abstract

We present, as a pure Prolog program, the first executable specification of the 3 + 3 dose-escalation protocol commonly used in early-phase oncology drug development. In this program, the imperative operations of the protocol emerge as consequences of clinically meaningful anticipatory-regret scenarios that are declared as CLP(Z) constraints. This 'regret-constrained' (RC) specification yields a robust formulation which can be used to prove clinically meaningful safety and liveness properties of the protocol before incorporating it into a trial, and then as an on-line decision support system while the trial is underway. Our RC specification also readily accommodates certain pragmatic modifications to trial enrollment which severely strain traditionally imperative formulations. The features of modern Prolog systems let us describe the 3 + 3 protocol with a short and general program that has desirable algebraic properties and can therefore be used, tested and reasoned about in several different ways.

arXiv comments
17 pages, 2 figures, 1 appendix
Journal reference
DOI
Subjects
cs.PLProgramming Languages

On Hacker News

Linked by 2 identifiable commenters in 3 comments across 3 threads, from Jul 2024 to Aug 2026. Found in 1 HN submission from Feb 2024 to Feb 2024. Open submission discussions.

Comments linking this paper, per year.

Discussed in comments3 threads

    • Thank you a lot for your interest! Yes of course: As I see it, Prolog is often awesome in types of applications that are distinct from those one would usually build in other kinds of languages. Alex Petros phrased it extremely nicely and insightfully in his comment at…

      triskaView on HNParent context

    • It's so much worse than you could possibly imagine. I worked for a healthcare startup working on patient enrollment for clinical oncology trials. The challenges are amazing. Quite frankly it wouldn't matter if the data were in plaintext. The diagnostic codes vary between…

      upghostView on HNParent context

    • > the links you provided describe these applications without references to warranties and standards and regulation. This is not true. For example, quoting from page 2 of the paper that is linked to in a discussion I posted, An Executable Specification of Oncology Dose-Escalation…

      triskaView on HNParent context